Select another Impact Assessment Method
Back to EPS default 2000

Characterisation Method Information
Characterisation Method Name:
HCI impact on YOLL
Version:
1999
Date Completed:
1999
Principal Method Name:
EPS: secondary aerosol pathway
Method Description:
YOLL stands for Year of Lost Life.

Model for secondary aerosol pathway

The characterisation factor is determined by a modified equivalency method using SO2 as
a reference.

Equivalency factor

An equivalency factor with SO2 is determined through the formula:
(MCl/MHCl) / (MSO4/MSO2) = 0.648, where
MCl and MHCl are the molecular weights of F - and HF, respectively, and MSO4 and MSO2
are the molecular weights of SO4 and SO2, respectively.

Calculation of pathway specific characterisation factor

The secondary aerosol pathway specific characterisation factor of SO2 for YOLL is
3.74E-05 YOLL/kg SO2, which thus will result in a characterisation factor for HCl of
0.648*3.74E-05 = 2.42E-05 YOLL/kg HCl.

Literature Reference:
Steen B (1999b): A systematic approach to environmental priority strategies in product development (EPS). Version 2000 Models and data of the default method CPM report Chalmers University of Technology Sweden
Methodological Range:
The system is global and the time period is 1990.
Notes:

Existing Characterisation Factors of HCI impact on YOLL
Characterisation Parameter Category Indicator Impact Indication Principle Aspect Substance Quantity Unit Notes
CFactor YOLL EPS/2000
Type = Emission
Direction = Output
Media = Air
Geography = *
HCl 2.42E-05 p yr/kg